Installing Piping to the Right Side (SV Frame)
1.
Unlock the tubing clamp, and route the indoor unit refrigerant piping and drain hose to the required
chassis access hole on the right side (A).
2.
Pull the field drain and refrigerant piping, and the connecting cable from the access hole in the wall.
3. Guide the connection cable into the indoor unit, but don’t attach to the terminals. (Make a small loop
in the cable for easy connection later.)
4.
Connect the indoor unit drain hose and piping to the field drain piping and refrigerant piping (B). (See
the “Connecting the Indoor Unit Piping to Field Piping” section for instructions.)
5. Tape the drain hose, piping, and the connecting cable together, and install insulation (B). (See the
“Piping Bundling” and “Insulating the Piping” sections for instructions.)
6.
Optional: Secure a clamp to the strap boss with a screw (C).
7. Reroute the field drain and refrigerant piping back into the wall, and, after connecting the power wiring
and communication cables to the terminals on the indoor unit, hang the indoor unit.
Figure 43: Piping Installation to
the Left Side.
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose
Drain hose
Clamp
Strap Boss
Screw
C
B
A
Wall Mounted Indoor Units
SV Frame
PIPING INSTALL
Figure 44: Piping Installation to
the Right Side.
Drain pipe
Connecting cable
B
A
C
Installing Piping to the Left Side (SV Frame)
1.
Unlock the tubing clamp, and route the indoor unit refrigerant piping and the drain hose to the
required chassis access hole on the left side (A). (See “Accessing the Indoor Unit Piping” for instruc
-
tions.)
2.
Pull the field drain piping and refrigerant piping, and the connecting cable from the access hole in the
wall.
3. Guide the connection cable into the indoor unit, but don’t attach to the terminals (B). (Make a small
loop in the cable for easy connection later.)
4.
Connect the indoor unit drain hose and piping to the field drain piping and refrigerant piping (C). (See
the “Connecting the Indoor Unit Piping to Field Piping” section for instructions.)
5. Tape the drain hose, piping, and the connecting cable together, and install insulation (C). (See the
“Piping Bundling” and “Insulating the Piping” sections for instructions.)
6.
Reroute the indoor unit drain hose and refrigerant piping across the back of the indoor unit, and lock
in place with the tubing clamp (C).
7. Reroute the field drain and refrigerant piping back into the wall, and, after connecting the power wiring
and communication cables to the terminals on the indoor unit, hang the indoor unit.