IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage
test or air purge. Do not compress air or Oxygen and do not use
Flammable gases. Otherwise, it may cause fire or explosion.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an oper-
ating gas appliance or an operating electric heater)
• Do not use means to accelerate the defrosting process or to
clean, other than those recommended by the manufacturer.
• Do not pierce or burn refrigerant cycle part.
• Be aware that refrigerants may not contain an odour.
• Keep any required ventilation openings clear of obstruction.
• The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
• Refrigerant tubing shall be protected or enclosed to avoid damage.
• Flexible refrigerant connectors (such as connecting lines be-
tween the indoor and outdoor unit) that may be displaced dur-
ing normal operations shall be protected against mechanical
damage.
• A brazed, welded, or mechanical connection shall be made be-
fore opening the valves to permit refrigerant to flow between
the refrigerating system parts.
• Mechanical connections shall be accessible for maintenance
purposes.
Operation
• When the product is soaked (flooded or submerged) in water ,
contact an Authorized Service Center for repair before using it
again. There is risk of fire or electric shock.
• Be sure to use only those parts which are listed in the svc
parts list. Never attempt to modify the equipment. The use of
inappropriate parts can cause an electrical shock, excessive
heat generation or fire.
• Do not touch , operate, or repair the product with wet hands.
Hold the plug by hand when taking out. There is risk of electric
shock or fire.
• Do not place a heater or other heating appliances near the
power cable. There is risk of fire and electric shock.