5-17
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
(TROUBLE 7) Grill
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
1. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Replace.
NOTE : • Make sure the wire leads are in the correct position.
• When removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Summary of Contents for MH-1446SQP
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 28: ...6 1 EXPLODED VIEW INTRODUCTION MODEL MH 1446SQP EV ...
Page 29: ...6 2 13213A 13552A 15006A 13581A 13536A 14026A 14970A 13720D 14890A DOOR PARTS EV ...
Page 30: ...6 3 23572A 24781M WTP018 268711 24510L 250201 24970A 23506A CONTROL PANEL PARTS EV ...
Page 32: ...6 5 43501A WSZ085 466001 466001 466003 43500A LATCH BOARD PARTS EV ...
Page 34: ...6 7 WTT021 63302A 63303A 56170D WSZ002 948502 65006B BASE PLATE PARTS EV ...
Page 35: ......