5-16
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay 2.
(Operate the unit)
Normal
Normal
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor.
Abnormal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer.
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode.
Normal
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.