4. TROUBLE SHOOTING
- 97 -
START
Change main board
SETTING : After initialize Agilent 8960, Test EGSM, DCS mode
Set the property of audio as PRBS or continuous wave. Set the receiving volume of mobile as Max.
Check the state of
soldering of receiver
YES
NO
Resolder receiver
R113,R115
Are well-solederd?
NO
YES
Resolder R113,R115
Folder connector
is well-connected?
NO
YES
Connect folder connect with FPCB
Checking Flow