11. AUTO CALIBRATION
- 135 -
11.1 Overview
Autocal (Auto Calibration) is the PC side Calibration tool that perform Tx ,Rx and Battery Calibration
with Agilent 8960(GSM call setting instrument) and Tektronix PS2521G(Programmable Power supply).
Autocal generate calibration data by communicating with phone and measuring equipment then write it
into calibration data block of flash memory in GSM phone.
11.2 Requirements
- PC or Notebook installed with Microsoft Windows 98/ME/2000/XP
- Auto Calibration program(Autocal.exe)
- GSM Phone
- LGE PIF JIG, Serial Cable, Data Cable
- Agilent 8960(Call Setting Instrument)
- Tektronix PS2521G(Programmable Power Supply)
11.3 Menu and Settings
- File(F) Clear View : Clear Calibration Status window texts
- File(F) Save View : Save Calibration Status window texts
- File(F) Save Setting : Save Current Calibration settings to setting file(*.cal)
- File(F) Load Setting : Load saved Calibration setting
- File(F) Make BIN ALL : Make binary file after calibration finished
- File(F) Make BIN BAT.Cal only : Make binary file of battery cal data only after calibration finished
- File(F) Make & Write BIN : Make binary file after calibration finished then download it to the Flash
Memory
- View(V) Tools : Enable or disable Tool bar
- View(V) Status : Enable or disable status bar
- Connection(C) Connect : Connect the phone with PC. This procedure checks whether the PC is
connected “ag8960 ” or not. After that it performs sync. procedure with
phone. If the sync. procedure is successful state column on status bar
changed to SETUP, else you should disconnect phone and try again from
the beginning and also check the whole connection. All measurement is
performed at state SETUP.
- Connection(C) Port Setting : Show COM port setting dialog and Baudrate you can change,etc.
- GPIB(G) Connect : Connect the Ag8960 GPIB card with PC.
11. AUTO CALIBRATION
Z3X-BOX.COM
Summary of Contents for MG300d
Page 23: ...3 TECHNICAL BRIEF 24 Figure 3 1 SKY74400 FUNCTIONAL BLOCK DIAGRAM Z 3 X B O X C O M ...
Page 83: ...4 TROUBLE SHOOTING 84 4 6 LCD Trouble EMI FILTER CN600 Test Points Z 3 X B O X C O M ...
Page 110: ...5 DOWNLOAD AND CALIBRATION 111 8 Push the START button Z 3 X B O X C O M ...
Page 111: ...5 DOWNLOAD AND CALIBRATION 112 9 Phone test Finish is shown in below screen Z 3 X B O X C O M ...
Page 112: ...6 BLOCK DIAGRAM 113 6 BLOCK DIAGRAM Z 3 X B O X C O M ...
Page 113: ... 114 Z 3 X B O X C O M ...
Page 124: ... 125 MG300d 8 PCB LAYOUT Z 3 X B O X C O M ...
Page 125: ... 126 MG300d 8 PCB LAYOUT Z 3 X B O X C O M ...
Page 137: ... 138 Z 3 X B O X C O M ...
Page 138: ... 139 Z 3 X B O X C O M ...
Page 140: ... 141 12 EXPLODED VIEW REPLACEMENT PART LIST Z 3 X B O X C O M ...
Page 141: ... 142 Z 3 X B O X C O M ...