Mount the installation plate horizontally by
aligning the centerline using a level.
A
Mount the installation plate on the wall with
four type A screws. If mounting the unit on a
concrete wall, use anchor bolts.
The wall you select should be strong and solid
enough to prevent vibration.
B
Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing of
the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
Installation Plate
Marking-off line
Thread
Weight
Type "A" screw
Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
Indoor
WALL
Outdoor
5
-7
m
m
(0
.2
~
0
.3
")
CAUTION
Make sure that the drilled hole in the wall is
properly sealed (using a proper sealant, for
example cement, plaster of paris etc.) after
passing the installation pipe, drainage pipe
and the inter connecting cable.
INSTALLATION OF INDOOR & OUTDOOR UNIT
How to fix installation plate
Drill a hole in the wall
Outdoor Unit
Drain Pipe
Drain Pan
Drain pan along with drain pipe (as
shown below) can be used to drain
the water accumulated in the outdoor
during the Heat Mode.
Left rear piping
Right rear piping
Hole center
ø70mm
"D"
"C"
Usage of Drain Pan
(Heat Pump)
INSTALLATION
9