h2
h1
h1
A
A
Branch Pipe
Main Pipe
Distributor
Distributor
B
B
h2
Multi Piping Type
Distributor Type
Installation of Indoor, Outdoor Unit
Installation Manual 7
ENGLISH
Multi Piping Type
(m)
Distributor Type
(m)
Piping length and elevation
14k/16k
30
20
15
7.5
18k
40
25
15
7.5
24k
50
25
15
7.5
30k
70
25
15
7.5
Capacity(Btu/h)
Total Length
Max Length(A/B)
Max Elevation
(h1)
In - In Elevation
(h2)
40k
100
50
50
15
30
10
48k
110
50
60
15
30
10
56k
120
50
70
15
30
10
Capacity
(Btu/h)
Total Length
Max Main Pipe
Length (A/B)
Total Branch
Pipe Length
Max Branch
Pipe Length
Max Elevation
(h1)
In - In Elevation
(h2)
CAUTION: Capacity is based on standard length and maximum allowance
length is on the basis of reliability. Oil trap should be installed every 5~7
meters.