Installation of Indoor, Outdoor Unit
8 Multi Type Air Conditioner
How to fix installation plate
Type 1.
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
Chassis
Hook
Installation Plate
Type “A”
Installation plate
Left rear piping
Right rear piping
Ø70mm
Ø70mm
D
B
A
C
• Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
A
B
C
D
S4
73
55
82
55
S5
121
62
258
62
CHASSIS
(Grade)
Distance (mm)
A
B
C
D
S4
50
105
59
105
SE
65
110
85
110
S5
95
122
235
122
CHASSIS
(Grade)
Distance (mm)
Installation plate
Left rear piping
Right rear piping
Ø70mm
Ø70mm
D
B
A
C