5-14
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace primary
and monitor
switches.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace primary
and monitor
switches.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
(TROUBLE 2) Oven does not operate at all ; Display window does not display any figures and
no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-6, 5-7
2. Fuse does not
blow.
No continuity.
No continuity.
Replace power
supply cord.
Defective mag-
netron thermostat.
Defective power
supply cord.
Replace mag-
netron thermostat.
Check continuity
of magnetron
thermostat.
Check continuity
of power supply
cord.
Continuity.
Summary of Contents for MB-4342A
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 29: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 30: ...6 3 WTP015 26638A 23572A 24781M 268711 23550D CONTROL PANEL PARTS ...
Page 32: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...
Page 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 36: ...8 2 PRINTED CIRCUIT BOARD ...
Page 37: ...P NO 3828W5S2647 Jan 2003 Printed in Korea ...
Page 39: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 40: ...6 3 WTP015 26638A 23572A 24781M 268711 23550D CONTROL PANEL PARTS ...
Page 42: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 44: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...