A. PRIMARY INTERLOCK SWITCH TEST
When the door release button is depressed slowly
with the door closed, an audible click should be
heard at the same time or successively at
intervals. When the button is released slowly, the
latches should activate the switches with an
audible click.
If the latches do not activate the switches when
the door is closed, the switches should be a
adjusted in accordance with the adjustment
procedure. Disconnect the wire lead from the
primary switch. Connect the ohmmeter leads to
the common (COM) and normally open (NO)
terminal of the switch. The meter should indicate
an open circuit in the door open condition.
When the door is closed, the meter should
indicate a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate a open circuit in
the door open condition. When the door is closed,
meter should indicate an closed circuit. When the
secondary switch operation is abnormal, make the
necessary adjustment or replace the switch only
with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate closed circuit in
the door open condition. When the door is closed,
meter should indicate an open circuit. When the
monitor switch operation is abnormal, replace with
the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
5-7
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
NOTE : After checking for the continuity of switches, make sure that are
connected correctly.
NO
COM
NC
COM
NO
COM
INTERLOCK CONTINUITY TEST
Secondary
Switch
Summary of Contents for MB-4342A
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 29: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 30: ...6 3 WTP015 26638A 23572A 24781M 268711 23550D CONTROL PANEL PARTS ...
Page 32: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...
Page 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 36: ...8 2 PRINTED CIRCUIT BOARD ...
Page 37: ...P NO 3828W5S2647 Jan 2003 Printed in Korea ...
Page 39: ...6 2 13581A 14970A 14026A 13552A 13536A 15006A 13213A 13720D 13352A DOOR PARTS ...
Page 40: ...6 3 WTP015 26638A 23572A 24781M 268711 23550D CONTROL PANEL PARTS ...
Page 42: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Page 44: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...