Service Manual 9
Product Specifications
* DB:Dry Bulb
** WB:Wet Bulb
NOTE: Please refer to Label Quality on the produst since this specification may be changed for improving performance.
LWC121CGMK0
LWC143CGMK0
LWC143CSMK0
POWER SUPPLY
COOLING CAPACITY
(Btu/h)
INPUT
(W)
RUNNING CURRENT
(A)
E.E.R
(BTU/W.h)
OPERATING
INDOOR (°C)
CONDITION
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
COMPRESSOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
(lbs/kg)
OUTSIDE DIMENSION
(inch)
(W x H x D)
(mm)
1Ø,115V,60Hz
1Ø,220V,60Hz
12,000
14,000
1,220
1,400
11
6.2
9.8
10
26.7(DB),19.4(WB)
35(DB),23.9(WB)
355g(12.5oz)
670g(23.6oz)
2 ROW 16STACKS
2 ROW 13STACKS
2 ROW 18STACKS
2 ROW 14STACKS
TURBO
PROPELLER TYPE FAN WITH SLINGER-RING
3/3
6 POLES
REMOTE CONTROLLER
THERMISTOR
VERTICAL LOUVER(RIGHT&LEFT)
HORIZONTAL LOUVER (UP&DOWN)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
(3 WIRE WITH GROUNDING)
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
95/43
23
5
/
8
x 14
31
/
32
x 22
5
/
16
600 x 380 x 567
MODELS
ITEMS
Specfications