Service Manual 23
Disassembly
9. Capacitor
1. Remove the control box. (Refer to section 3)
2. Remove the knobs and the screw that fasten
control panel from control box.
3. Remove the screw located in the front.
4. Open the bottom side of control box.
5. Remove the screw and the clamp that fastens
the capacitor.
6. Disconnect all the leads of capacitor terminals.
7. Re-install the components by referring to the
removal procedure, above. (See Figure 24)
10. Power Cord
1. Remove the control box. (Refer to section 3)
2. Open the control box. (Refer to section 9)
3. Disconnect the grounding screw from the control
box.
4. Disconnect the 2 receptacles.
5. Remove the screw that fastens the clip cord.
(See Figure 25)
6. Remove the power cord.
7. Re-install the component by referring to the
above removal procedure, above.
(Use only one ground-marked hole
for ground
connection.)
8. If the supply cord of this appliance is damaged, it
must be replaced by the special cord. (The
special cord means the cord that has the same
specification marked on the supply cord attached
at the unit.)
11. Thermostat
1. Remove the control box. (Refer to section 3)
2. Open the control box. (Refer to section 9)
3. Remove the 2 screws that fasten the thermostat.
4. Disconnect 2 leads of thermostat terminals.
5. Remove the thermostat.
6. Re-install the components by refereing to the
above removal procedure. (See Figure 26)
12. Rotary Switch
1. Remove the control box. (Refer to section 3)
2. Open the control box. (Refer to section 9)
3. Remove the 2 screws that fasten the rotary
switch.
4. Disconnect all the leads of the rotary switch ter-
minals.
5. Remove the rotary switch.
6. Re-install the components by referring to the
above removal procedure. (See Figure 27)
Figure 27
Figure 24
Figure 25
Figure 26
Summary of Contents for LWC121CGMK0