ENGLISH
9
INSTALLATION
INSTALLATION
Electrical Data
Power cord may include a current interrupter
device.
TEST
and
RESET
buttons are provided
on the plug case. The device should be tested on
a periodic basis by first pressing the
TEST
button
and then the
RESET
button. If the
TEST
button
does not trip or if the
RESET
button will not stay
engaged, discontinue use of the air conditioner
and contact a qualified service technician.
for 240 V
RESET
TEST
Use Wall Receptacle
Power Supply
Use 20 A, time
delay fuse or 20 A,
circuit breaker.
Standard 240 V, 3-wire
grounding receptacle rated
20 A / 240 VAC / 60 Hz
WARNING
●
This appliance should be installed in
accordance with the National Electrical
Code.
●
Use of extension cords could cause serious
injury or death.
-Do not use an extension cord with this
window air conditioner.
-Do not use surge protectors or multi-outlet
adapters with this window air conditioner.
●
Never push the
TEST
button during
operation. Doing so can damage the plug.
-Do not remove, modify, or immerse this
plug. If this device trips, the cause should
be corrected before further use.
CAUTION
●
The conductors inside this cord are
surrounded by shields, which monitor
leakage current. These shields are not
grounded. Periodically examine the cord
for any damage. Do not use this product
in the event the shields become exposed.
Avoid shock hazard. This unit cannot be
user-serviced. Do not open the tamper-
resistant sealed portion. All warranties and
performance will be voided. This unit is not
intended to be used as an ON/OFF switch.