ENGLISH
11
INSTALLATION
Window Requirements
●
This unit is designed for installation in standard
double hung windows with actual opening
widths from 29" to 41".
The top and bottom window sashes must open
19" from the bottom of the upper sash to the
inside sill.
●
The height offset between the inside sill and
outside sill must be less than 1 ¼".
29" to 41"
19" min
NOTE
●
wood, masonry, or metal.
Preparation of Cabinet
1
Remove 4 screws which fasten the cabinet
at both sides and at the back. (Keep the
screws for later use.)
2
Slide the unit from the cabinet by gripping
the base pan handle and pulling forward
while bracing the cabinet.
3
Cut the window sash seals (Foam-PE)
to the proper length. Peel off the backing
and attach the adhesive-backed foam to
the underside of the window sash and the
bottom of the window frame.
Shipping
Screws
CAUTION
●
The unit is heavy. To prevent injury, use
proper lifting techniques when pulling unit
forward from cabinet. Obtain assistance
from another person if possible.
Foam-PE
(Adhesive backed)
Summary of Contents for LW2516ER