background image

- 3 -

Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

Note :

• O: Applied, • X: Not applied, • - : No relation,
• Option: Model name & price are different according to options, and assembled in factory with main unit.
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.

Defrost / Deicing
High pressure switch
Low pressure switch

Reliability

Phase protection
Restart delay (3-minutes)
Self diagnosis
Soft start
Test function

Convenience

Auto operation(Artificial intelligence)
Auto restart operation

CAC network

Network soluation(LGAP)

function

PDI(Power Distribution Indicator)
PI485

Special 

Low ambient operation

function kit
Others

Thermistor

Function

Category

AUUW243D

O
O

X
X

O
O
O

X

O
O

X
X
X

O(Program Logic)

-

2. Function Table

Outdoor Unit

Summary of Contents for LUU245HV

Page 1: ...er SVC MANUAL Exploded View MODEL AUUW243D LUU245HV CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Page 2: ...in Rating Max Heating kW Nominal Capacity Cooling Btu h Min Rating Max Heating Btu h Nominal Input Cooling kW Min Rating Max Heating kW Indoor Unit Indoor Unit ATNH243PLAD APNH2433LAD 24 000 26 000 2 40 2 50 24 000 26 000 2 50 2 55 Outdoor Unit Compressor Type Refrigerant Charge Charge g oz Type Fan Discharge Side Top Noise Level H L Sound Press 1m dB A 3 Dimensions W H D mm inch Net Weight Outdoo...

Page 3: ...he corresponding model name supplied with separate package Defrost Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay 3 minutes Self diagnosis Soft start Test function Convenience Auto operation Artificial intelligence Auto restart operation CAC network Network soluation LGAP function PDI Power Distribution Indicator PI485 Special Low ambient operation func...

Page 4: ...LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only LOC Description PCB Connector EEV Electronic Expansion Valve CN_LEV1 Th1 Thermistor for suction pipe temperature CN_TH3 Th2 Thermistor for discharge pipe temperature CN_TH3 Th3 Thermistor for condenser pipe temperature CN_TH2 Th4 Thermistor for outdoor air temperature CN_TH2 Th5 Thermistor for conden...

Page 5: ...onics Inc All right reserved Only for training and service purposes LGE Internal Use Only CN 4WAY CN PFC OUT CN PFC IN CN CN CN FLASH CN LGMV CN CN CP N CN CP L TH3 TH4 TH2 CN MOTOR1 CN EEV1 CN COM Outdoor Unit 4 Wiring Diagrams ...

Page 6: ...5512 437210 435511B W6200 552116 552203B 552203A 549610 447910 552117 661400 55211G 649950 135500B 552113 567480C 567480B 435511A 268711F 352111B 430410 546810 263230C 561410 W6640 550140 Note Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz Lgservice com 5...

Page 7: ...P NO MFL62129301 MARCH 2009 ...