- 2 -
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose of
improvement.
Indoor Unit
Nominal Capacity
Cooling
Btu/h
(Min~Rating~Max)
Heating
Btu/h
Nominal Input
Cooling
kW
(Min~Rating~Max)
Heating
kW
Nominal Capacity
Cooling
Btu/h
(Min~Rating~Max)
Heating
Btu/h
Nominal Input
Cooling
kW
(Min~Rating~Max)
Heating
kW
Indoor Unit
Indoor Unit
ATNH243PLAD
APNH2433LAD
24,000
26,000
2.40
2.50
24,000
26,000
2.50
2.55
Outdoor Unit
Compressor
Type
Refrigerant Charge
Charge*
g(oz)
Type
Fan
Discharge
Side/Top
Noise Level(H/L)
Sound Press,1m
dB(A)±3
Dimensions W*H*D
mm
(inch)
Net Weight
Outdoor
kg(lbs)
Piping connections
Liquid
mm (inch)
Gas mm
(inch)
Power Supply Cable(Includes earth)
No.*AWG
Interunit Cable(Includes earth)
No.*AWG
Max. Piping Length/Elevation
m(ft)
Power Supply
Ø,V,Hz
Running Current
Cooling/Heating
A
Air Circulation
CMM(CFM)
Additional Refrigerant Charge (Over 7.5m)
g/m(oz/ft)
Operation Range
Cooling
°C(°F)
Heating
°C(°F)
Indoor Unit
AUUW243D
Rotary
2000(70.6)
R410A
side
55
870*808*320(34.3*31.8*12.6)
60(132)
9.52 (3/8)
15.88 (5/8)
No.*12
No.*18
50(164)/30(98)
1, 208~230, 60
10.0/10.7
58(2048)
35(0.38)
-10(14) ~ 43(109.4)
-15(5) ~ 24(75.2)