3-11
COmpONENT ACCESS
REmOvING ThE BROIL ELEmENT
5. Release 2 hooks and remove 4 screws.
4 Screws
2 Hooks
6. Remove 2 screws and separate the broil assembly from the upper
cavity.
2 Screws
WARNING
• DISCONNECT power supply cord from the outlet
before servicing.
• Replace all panels and parts before operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal injury, death or
electric shock.
CAUTION
• Use caution when handling sheet metal parts
while servicing the range.
- Some parts may have sharp edges, which could result in injury.
1. Turn off the electrical supply going to the range.
2. remove the back cover, cooktop plate, manifold panel and cooling
fan(see page 3-2, 3-4, 3-8 and 3-9 for the procedure).
3. Remove the upper case (see page 3-9 for the procedure).
4. Unplug 2 connectors at each point.
2 Connectors