9) Over cooling in Refrigerator room
No
Checking flow
2
Reset the unit and
Input Test 1 Mode.
(push the button 1 time)
3
Open the refrigerator door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the PCB
Status
Windy
No windy
SVC Action
Change the PCB
It ’s normal
4
Input Test 2 Mode and
Check the air flow.
(push the button 1 time)
1
1.- Unplug connector from CON8.
2.- Check resistance in wires White to
White.
- 51 -