8) Poor cooling in Refrigerator room
No
Checking flow
2
Reset the unit and
Input Test 1 Mode.
(push the button 1 time)
3
Open the freezer door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the Fan motor
(Next page)
Status
Cold
Not cold
SVC Action
Normal
Check the Compressor
And sealed system
4
Check the air temperature.
Cold or not ?
1
1.- Unplug connector from CON8.
2.- Check resistance in wires White to
White.
Release
Motor
Point
Result
SVC Action
5
Check the Fan motor.
Rotate fan using your hand.
It feel sticky, change the motor.
(cause of ice or rust inside of motor)
Check section
Cooling
BLDC Fan
Motor Error
- 50 -