4-1 ANOTHER ELECTRIC COMPONENTS
Poor contacting.
Coil is shorted.
Shorted.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
Def. Sensor
FUSE-M
Check current flowing
of the following
components.
Heater plate
Heater cord
Fan motor doesn't run.
Much frost are sticked
to the EVAPORATOR.
Replace each
component.
Replace each
component.
Replace each
component.
U
W
V
Multi
Tester
U
W
V
Compressor terminal
Motor resistance
7.96 ± 1 \
Compressor
BMA069LAMV
There may be difference of several \ in the resistance value according to the
ambient temperature or operation condition.
Cooling ability is poor
Check COMPRESSOR & HARNESS
Q
Measure COMP connector resistance (Power & Common)
Check insulation destruction : measure the resistance between the COMP
power connector and the grounding.
Q