17
Connections
While operating
Auto Pan func-
tion.
Stop auto panning and change
the observe position to the
alarmed position then keep
observe the alarmed position.
While operating
Pattern function.
Stop operating pattern function
and change the observe posi-
tion to the alarmed position then
keep observe the alarmed posi-
tion.
Auto mode: Change the observe position to a
sensor that senses a touch or shock then return
to the position that previously observed. (Set the
Duration Time of Alarm Input function to “1 to
255”.)
<Example : If this unit receives signal from “Alarm 4”>
Preset 1
Preset 2
Preset 3
Alarm 1
Alarm 2
Alarm 3
Preset 4
Alarm 4
Alarm signal
input
Before inputting
the alarm signal
Released
alarm signal
Function status
Auto mode
While observe a
specific position.
Change the observe position to
the alarmed position then return
to the position that previously
observed.
While operating
Preset Tour func-
tion.
Stop preset touring and change
the observe position to the
alarmed position then restart the
preset touring again.
While operating
Auto Pan func-
tion.
Stop auto panning and change
the observe position to the
alarmed position then restart the
auto panning again.
•
While operating
Pattern function.
Stop operating pattern func-
tion and change the observe
position to the alarmed position
then restart the pattern function
again.
Note:
The Alarm In 1 is Preset 1, Alarm In 2 is Preset 2,
Alarm In 3 is Preset 3 and Alarm In 4 is Preset 4.
Connecting LKD1000 controller
Connecting the LKD1000 controller to control the cam-
era. (Refer to the manuals of the LKD1000 controller
for more details.).
TX+
TX-
Data Port Adapter
LKD1000 controller