Compressor
To reduce noise level, the piston stroke is slowly increased to full power during start up.
There are 6 protection logics designed to protect the linear compressor system. When a failure is detected,
the compressor will shut and will try to restart after a set period of time for each type of failure. The LED
located on the inverter drive PCB will flash the appropriate code to indicate the detected failure. This code will
continue to flash until the unit is disconnected from the power source.
Inverter Error Codes
Step 1) Start up - Half stroke interval for first 30
seconds.
Step 2) Ramp up - Stroke increases every 0.8sec until
maximum stroke length is reached (about 3
min, 15 sec)
Step 3) CVCF interval - 180V / 60Hz
Step 1) Start up - Half stroke interval for first 20
seconds.
Step 2) Ramp up - Stroke increases until maximum
stroke length is reached (about 1 min, 40 sec)
Step 3) VVCF interval - target voltage and frequency
controlled by Control Board signals
Inverter Error
Codes
code
Requirement
Off Time
The number
of LED
flashes
FCT0
5
|Vm, Im|> 2.5V+20% @ COMP off
30s
1
Stroke
10
|Stroke|>17.5mm
60s
2
No Connect
15
|Stroke|<=9.4mm &
While 4 seconds |AC Current|<0.05A
40s
3
Lock
25
|AC Current|>1.0A & |Stroke|<3.0mm
150s
5
Current
30
|Current|>3Ap
360s
6
IPM
35
uc_Fo_Trip!= 0
20S
7
Communication
Error
-
Checksum error
0
8
Summary of Contents for LSXS26326
Page 9: ...Circuit Diagram ...
Page 25: ...Micom Circuit description ...
Page 31: ...Compressor ...
Page 33: ...Compressor ...
Page 34: ...Compressor ...
Page 35: ...Compressor ...
Page 50: ...Troubleshooting ...
Page 52: ...Troubleshooting ...
Page 54: ...Troubleshooting ...
Page 55: ...Troubleshooting 2 9 Communication Error CO E ...
Page 78: ...August 2014 MFL ...