LED operating condition
Cause
No.
1
Service guide
LED blinking 1 time repeatedly
Blink -Off-Blink-Off-Blink-Off-Blink-Off-Blink-Off
Repeat
PCB part
defect
(MICOM)
1. After resetting the power check
normal operation
2
. When the same symptom occurs
again after taking action for 1,
replace the PCB
2
LED blinking 1 time repeatedly
PCB part
defect (Piston
over-operation)
1.After resetting the power check
normal operation
2.When the same symptom
occurs again after taking action
for 1, replace the PCB
4
LED blinking 4 time repeatedly
COMP cable
contact error
1.Check connected condition
between PCB and COMP
2.When there is no issue with 1,
replace the PCB
5
LED blinking 5 time repeatedly
Piston lock
1.After resetting the power check
normal operation
2.When the same symptom
occurs again after taking action
for 1, replace the PCB
3.
When the same symptom occurs
again after taking action for 2,
replace the COMP component
7
LED blinking 7 time repeatedly
PCB part
defect (IPM)
1.After resetting the power check
normal operation
2.When the same symptom
occurs again after taking action
for 1, replace the PCB
8
LED blinking 8 time repeatedly
Communication
error
1.After resetting the power check
normal operation
2.When the same symptom
occurs again after taking action
for 1, replace the PCB
6
LED blinking 6 time repeatedly
Circuit over-
current error
1.After resetting the power check
normal operation
2.When the same symptom
occurs again after taking action
for 1, replace the PCB
3.When the same symptom
occurs again after taking action
for 2, replace the COMP
component
3
LED blinking 3 time repeatedly
Power voltage
defect)
1.Check input power
2.After resetting the power check
normal operation
3.When the same symptom
occurs again after taking action
for 1 and 2 replace the PCB
4. Resolution by number of LED blinks
Troubleshooting
Summary of Contents for LSXC22326
Page 9: ...Circuit Diagram ...
Page 25: ...Micom Circuit description ...
Page 31: ...Compressor ...
Page 33: ...Compressor ...
Page 34: ...Compressor ...
Page 35: ...Compressor ...
Page 50: ...Troubleshooting ...
Page 52: ...Troubleshooting ...
Page 54: ...Troubleshooting ...
Page 55: ...Troubleshooting 2 9 Communication Error CO E ...
Page 78: ...August 2014 MFL62215930 ...