5-2
CONVERSION TO LP GAS
WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
4. CONVERTING THE SURFACE BURNERS
Remove the conversion kit
(see illustration below).
LP orifice spuds have a orifice code on the top or
the side, denoting the location on the range
where it is to be installed.
1) Remove grates, burner caps and burner
heads.
2) Remove the brass orifice spud in the chimney
of each burner using a 13/32” or 10 mm nut
driver.
3) Install the LP orifice spuds into their correct
positions as described previously.
Orifice Locations for LP Gas
Conversion Kit
BURNER OUTPUT RATINGS; BTU/HR
BTU RATE
ORIFICE CODE
LSRG309ST
LSRG309ST
LF
LR
RR
RF
INNER
OUTER
CTR
BROIL
BAKE
9,500
9,100
5,000
15,000
8,000
14,000
18,000
L
M
P
K
J
R
C
D
LP (Propance) Gas, 10” W.C.P
Denotes
orifice
code
Top burner orifices
Broil and Bake
burner orifices
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
Screw
M
R
J
L
P
K
BURNER
MODEL