![LG LSGL6337D Service Manual Download Page 39](http://html.mh-extra.com/html/lg/lsgl6337d/lsgl6337d_service-manual_218442039.webp)
4-3
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
Components
Test procedures
Results
Door Switch
(Normally Closed type)
1. Refer to page 3-9 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Continuity
Infinite
Oven Lamp
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
30 Ω ± 10%
Broil or Bake Igniter
1. Refer to page 3-10 ~ 3-11 for servicing
procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: 45 Ω ~ 400 Ω
(Room Temperature
Resistance)
Summary of Contents for LSGL6337D
Page 88: ......