TROUBLE DIAGNOSIS
-58
-
K
C
E
H
C
O
T
W
O
H
.
S
T
N
I
O
P
K
C
E
H
C
D
N
A
S
E
S
U
A
C
.
S
M
I
A
L
C
8. Faulty lamp
(freezer and
refrigerator
compartment).
9. Faulty internal
voltage (short).
1) Lamp problem.
Filament blows out.
Glass is broken.
2) Bad lamp assembly.
Not inserted.
Loosened by vibration.
3) Bad lamp socket.
Disconnection.
Bad soldering.
Bad rivet contact.
Short.
Water penetration. Low water
level in tray.
Bad elasticity of contact.
Bad contact(corrosion).
4) Door switch.
Defective.
Refrigerator and freezer switches are reversed.
Travlel distance.
Bad connection.
Bad terminal contact.
Adiabatics liquid leak..
1) Lead wire is damaged.
Wire damage when assembling PTC Cover.
Outlet burr in the bottom plate.
Pressed by cord heater. lead wire, evaporator pipe.
2) Exposed terminal.
Compressor Compartment terminal. - Touching other
components.
Freezer compartment terminal. - Touching evaporator pipe.
3) Faulty parts.
Transformer.
Coil contacts cover.
Welded terminal parts contact cover.
Compressor.
Bad coil insulation.
Plate heater.
Melting fuse.
Sealing is broken.
Moisture penetration.
Cord heater.
Pipe damaged.
Moisture penetration.
Bad sealing.
Sheath heater.
Connect conduction and
non-conduction parts and
check with tester.
Conduction: NG.
Resistance
∞
: OK.
Summary of Contents for LSC27926
Page 19: ......
Page 25: ...EXPLANATION FOR MICOM CIRCUIT 25 ...
Page 35: ...EXPLANATION FOR MICOM CIRCUIT 35 ...
Page 36: ...EXPLANATION FOR MICOM CIRCUIT 36 ...
Page 37: ...EXPLANATION FOR MICOM CIRCUIT 37 ...
Page 38: ... 38 ...
Page 39: ...EXPLANATION FOR MICOM CIRCUIT 39 ...
Page 40: ... 40 ...
Page 41: ... 41 ...
Page 47: ...4 Ice Maker Circuits ICEMAKERANDDISPENSERWORKINGPRINCIPLESANDREPAIR 47 ...
Page 49: ...CIRCUIT 3854JK1010C 49 ...
Page 83: ...3 6 Brazing Reference Drawings TROUBLE DIAGNOSIS 83 ...
Page 94: ... EV EXPLODED VIEW FREEZER DOOR PART 200A 241F 241G 201A 203A 241G 241E 700A 243A 94 212J ...
Page 101: ...February 2009 MFL62215904 ...