2. No cooling.
2) Refrigeration system is clogged.
Heat a clogged evaporator to
check it. As soon as the
cracking sound starts, the
evaporator will begin to
freeze.
The evaporator does not cool
from the beginning
(no evidence of moisture
attached).
The evaporator is the same
as before even heat is
applied.
Moisture
clogged.
No electric
power on
thermo-
stat.
Weld joint
clogged.
Drier clogging.
Foreign material clogging.
Residual moisture
in the evaporator.
Residual moisture.
Insufficient drier
capacity.
Residual moisture
in pipes.
Moisture penetration - Leave it in the air. - Moisture penetration.
into the refrigeration oil.
Caps are missed.
Air blowing.
During transportation.
During work.
Not performed.
Performed.
Too short time.
Low air pressure.
Less dry air.
Air Blowing.
Leave it in the air.
Caps are missed.
Short pipe insert.
Pipe gaps.
Too much solder.
Too large.
Damaged pipes.
Not dried in the compressor.
Elapsed more than 6 months after drying
Caps are missed.
No pressure when it is open.
During rest time.
After work.
Compressor cap is disconnected.
Foreign materials are in the pipe.
Not performed.
Too short.
Impossible moisture
confirmation.
Low air pressure.
Dry drier - Drier temperature.
Leave it in the air.
The capillary tube inserted depth. - Too much.
Capillary tube melts. - Over heat.
Clogged with foreign materials.
Reduced cross section by cutting. - Squeezed.
Desiccant powder.
Weld oxides.
Drier angle.
Check on package
condition.
Good storage after
finishing.
-51-
Summary of Contents for LSC27926
Page 19: ......
Page 25: ...EXPLANATION FOR MICOM CIRCUIT 25 ...
Page 35: ...EXPLANATION FOR MICOM CIRCUIT 35 ...
Page 36: ...EXPLANATION FOR MICOM CIRCUIT 36 ...
Page 37: ...EXPLANATION FOR MICOM CIRCUIT 37 ...
Page 38: ... 38 ...
Page 39: ...EXPLANATION FOR MICOM CIRCUIT 39 ...
Page 40: ... 40 ...
Page 41: ... 41 ...
Page 47: ...4 Ice Maker Circuits ICEMAKERANDDISPENSERWORKINGPRINCIPLESANDREPAIR 47 ...
Page 49: ...CIRCUIT 3854JK1010C 49 ...
Page 83: ...3 6 Brazing Reference Drawings TROUBLE DIAGNOSIS 83 ...
Page 94: ... EV EXPLODED VIEW FREEZER DOOR PART 200A 241F 241G 201A 203A 241G 241E 700A 243A 94 212J ...
Page 101: ...February 2009 MFL62215904 ...