TROUBLE DIAGNOSIS
- 69 -
Problems
Causes
Checks
Measures
Remarks
High
Cycle pipe is clogged.
Check sequence.
- Heat up compressor discharging
Direr must be replaced.
temperature in
1. Check temperature of condenser
weld joints with touch, disconnect
the freezer
manually.
the pipes, and check the clogging.
compartment.
If it is warm, OK.
Remove the causes of clogging,
If it is not, compressor discharging
weld, evacuate, and recharge
joints might be clogged.
the refrigerant.
2. Manually check whether hot line
- If it's warm, OK. If it's not,
pipe is warm.
condenser discharging line weld
If it is warm, OK.
joints might be clogged.
If it is not, condenser outlet weld
Disconnect with torch, remove the
joints might be colgged.
causes, evacuate, and recharge
seal refrigerant.
Leak at loop pipe weld joint
Check sequence.
Replace the compressor, weld,
Drier must be replaced.
(discharge) in compressor.
1. Manually check whether
evacuate, and recharge refrigerant.
condenser is warm, It is not warm
and the frost forms partly on the
evaporator in the freezer
compartment.
Faulty cooling fan in the compressor
Check sequence.
- Replace if motor does not operate.
compartment.
1. Check cooling fan operation.
- If fan is disconnected, check fan
2. Check that cooling fan is
damage and reassemble it.
disconnected from the motor.
■
Refer to fan motor disassembly
and assembly sequence.
Summary of Contents for LSC 26945SW
Page 33: ...1 8 Stepping motor operation circuit 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 33 ...
Page 43: ...2 2 Parts list 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 43 ...
Page 44: ...EXPLANATION FOR MICOM CIRCUIT 44 ...
Page 45: ...2 3 DISPLAY ASSEMBLY part diagram 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 45 ...
Page 46: ...2 4 DISPLAY circuit diagram 1 LSC26945TT LSC26945SW 46 ...
Page 48: ...EXPLANATION FOR MICOM CIRCUIT 48 ...
Page 55: ... 1 LSC26945TT LSC26945SW CIRCUIT 55 3854JD1125C ...