2-8. Control of variable type of freezing fan
1. To increase cooling speed and load response speed, MICOM variably controls freezing room fan motor at the high speed
of RPM and standard RPM.
2. MICOM only operates in the input of initial power or express freezing operation or load response operation for the high
speed of RPM and operates in the standard RPM in other general operation.
3. If opening doors of freezing / cold storage room or home bar while fan motor in the freezing room operates, the freezing
room fan motor normally operates (If being operated in the high speed of RPM, it converts operation to the standard
RPM). However, if opening doors of freezing room or home bar, the freezing room fan motor stops.
4. As for monitoring of BLDC fan motor error in the freezing room, MICOM immediately stops the fan motor by determining
that the BLDC fan motor is locked or poor if there would be position signal for more than 115 seconds at the BLDC motor.
Then it displays failure (refer to failure diagnosis function table) at the display part of refrigerator, the BLDC motor doesn’t
operate more. If you want to operate the BLDC motor, turn off and on power resource.
2-9. Control of cooling fan motor
1. The cooling fan motor performs ON/OFF control by linking with the COMP.
2. It controls at the single RPM without varying RPM.
3. Failure sensing method is same as in fan motor of freezing fan motor (refer to failure diagnosis function table for failure
display).
2-10. Door opening alarm
1. Buzzer generates alarm sound if doors are not closed even when more than a minute consecutively has passed with
doors of freezing / cold storage room or home bar opened.
2. Buzzer rings three times in the interval of 0.5 second after the first one-minute has passed after doors are opened and
then repeats three times of On/Off alarm in the cycle of every 30 seconds.
3. If all the doors of freezing / cold storage room or home bar are closed during door open alarm, alarm is immediately
released.
2-11. Ringing of button selection buzzer
1. If pressing the front display button, “Ding ~ “ sound rings.
MICOM FUNCTION
- 17 -
Doors of freezing /
cold storage room
or home bar
BUZZER
Closing
Opening
Within
a minute
A minute
30
seconds
30
seconds
30
seconds
Opening
Closing
Closing
3 Times 3 Times 3 Times 3 Times
Summary of Contents for LSC 26945SW
Page 33: ...1 8 Stepping motor operation circuit 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 33 ...
Page 43: ...2 2 Parts list 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 43 ...
Page 44: ...EXPLANATION FOR MICOM CIRCUIT 44 ...
Page 45: ...2 3 DISPLAY ASSEMBLY part diagram 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 45 ...
Page 46: ...2 4 DISPLAY circuit diagram 1 LSC26945TT LSC26945SW 46 ...
Page 48: ...EXPLANATION FOR MICOM CIRCUIT 48 ...
Page 55: ... 1 LSC26945TT LSC26945SW CIRCUIT 55 3854JD1125C ...