12
Single Zone Mega and Mega 1
15V W
all Mounted Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
GENERAL DATA
Electrical
Nominal
Tons
Unit Model
No.
Hertz Voltage
Voltage
Range (Min.
to Max.)
MCA MOP
Com-
pressor
Quantity
Compressor Motor
RLA
Outdoor Fan
Motor
Indoor Fan Motor
Cooling Heating
W
FLA
W
FLA
3/4
LS090HEV2
60 208 - 230
187 - 253
10.0
15
1
7.0
7.0
43
0.4
30
0.4
1
LS120HEV2
10.0
15
1
7.0
7.0
43
0.4
30
0.4
1-1/2 LS180HEV2
15.0
20
1
10.0
10.0
85
0.4
58
0.4
2
LS240HEV2
15.0
20
1
10.0
10.0
85
0.4
58
0.4
Table 3: 208-230V, 60Hz, 1-Phase Single-Zone Mega System Electrical Data Table.
Table 4: 115V, 60Hz, 1-Phase Single Zone Single-Zone Mega 115V System Electrical Data Table.
Voltage tolerance is ±10%.
Maximum allowable voltage unbalance is 2%.
MCA = Minimum Circuit Ampacity.
Maximum Overcurrent Protection (MOP) is calculated as follows: (Largest motor FLA x 2.25) + (Sum of
other motor FLA) rounded down to the nearest standard fuse size.
RLA = Rated Load Amps.
FLA = Full Load Amps.
Voltage tolerance is ±10%.
Maximum allowable voltage unbalance is 2%.
MCA = Minimum Circuit Ampacity.
Maximum Overcurrent Protection (MOP) is calculated as follows: (Largest motor FLA x 2.25) + (Sum of
other motor FLA) rounded down to the nearest standard fuse size.
RLA = Rated Load Amps.
FLA = Full Load Amps.
Nominal
Tons
Unit Model
No.
Hertz Voltage
Voltage
Range (Min.
to Max.)
MCA MOP
Com-
pressor
Quantity
Compressor Motor
RLA
Outdoor Fan
Motor
Indoor Fan Motor
Cooling Heating
W
FLA
W
FLA
3/4
LS090HXV2
60
115
98-132
15
25
1
11.0
11.0
43
0.4
30
0.4
1
LS120HXV2
15
25
1
11.0
11.0
43
0.4
30
0.4