Product data | 11
Product Data
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG ” is a registered trademark of LG Corp.
System Model number (IDU/oDU)
LS090HSV4
(LSn090HSV4/LSU090HSV4)
LS120HSV4
(LSn120HSV4/LSU120HSV4)
LS180HSV4
(LSn180HSV4/LSU180HSV4)
Cooling Capacity (Min/Rated/Max) (Btu/h)
1,023 ~ 9,000 ~ 12,625
1,023 ~ 11,200 ~ 13,785
3,070~18,200~29,515
Cooling Power Input
1
(kW)
0.68
0.90
1.45
Heating Capacity (Min/Rated/Max) (Btu/h)
1,023 ~ 10,800 ~ 17,061
1,023 ~ 13,300 ~ 22,178
3,070 ~ 22,000 ~ 38,898
Heating Power Input
1
(kW)
0.70
1.0
1.76
CoP
4.51
3.90
3.66
Maximum Heating Capacity (Btu/h)
outdoor 17 °F (WB)/Indoor 70 °F (DB)
8,856 (82%)
10,906 (82%)
18,040 (82%)
outdoor 5°F (WB)/Indoor 70 °F (DB)
7,452 (69%)
9,177 (69%)
15,180 (69%)
outdoor -4 °F (WB)/Indoor 70 °F (DB)
7,236 (67%)
8,911 (67%)
14,740 (67%)
EER
13.3
12.5
12.6
SEER
21.5
21.5
20.5
HSPF
10.8
11.0
9.7
Power Supply (V/Hz/Ø)
208-230/60/1
ODU Operating Range
2
Cooling (°F DB)
14 to 118
Heating (°F WB)
-4 to +65
IDU Operating Range
Cooling (°F WB)
53 to 75
Heating (°F DB)
60 to 86
Indoor Temperature Setting Range
Cooling (°F)
64 to 86
Heating (°F)
60 to 86
Unit Data
Refrigerant Type
3
R410A
Refrigerant Control
EEV
IDU Sound Pressure
4
dB(A) (H/M/L/Sleep)
38/33/23/19
39/33/23/19
45/40/35/29
oDU Sound Pressure
4
dB(A)
45
45
53
Unit Weight (lbs)
IDU (net/Shipping)
20/26
20/26
31/36
oDU (net/Shipping)
75/79
75/79
121/131
Power/Communication Cable
5
(no. x AWG)
4 x 18
Compressor
Compressor Type (Qty)
Single Rotary (1)
Single Rotary (1)
Twin Rotary (1)
Fan
IDU Type (Qty)
Cross Flow (1)
oDU Type (Qty)
Propeller (1)
Motor/Drive
Brushless Digitally Controlled/Direct
Airflow Rate
IDU Max/H/M/L (CFM)
423/353/272/191
423/353/272/191
735/622/509/399
oDU Max (CFM)
1,165
1,165
2,119
Piping
Liquid Line (in, oD)
1/4
1/4
3/8
Vapor Line (in, oD)
3/8
3/8
5/8
Condensation Line (oD, ID)
27/32, 5/8
27/32, 5/8
27/32, 5/8
Additional Refrigerant Charge (oz/ft)
0.22
0.22
0.38
Pipe Length
6
(Minimum/Maximum)(ft)
6.6/65.6
6.6/65.6
9.84/98.4
Piping Length
6
(no add’l refrigerant, ft)
41.0
41.0
24.6
Max Elevation Difference (ft)
32.8
32.8
49.2
Table 2: Single Zone High Efficiency System Specifications.
generAl DATA
EEV: Electronic Expansion Valve IDU: Indoor Unit oDU: outdoor Unit
1
Power Input is rated at high speed.
2
optional low Ambient Wind Baffle Kit allows operation down to 0°F in cooling mode.
3
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy R410A
refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608 of CAA.
4
Sound Pressure levels are tested in an anechoic chamber under ISo Standard 1996.
5
All power wiring/communication cables are field supplied and are to be minimum 18 AWG, 4-conductor,
stranded, shielded and must comply with applicable local and national codes.
6
Piping lengths are equivalent.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level with 24.6 of refrigerant line per indoor unit and a 0 ft level
difference outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 59ºF wet
bulb (WB) and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).