2. Sensor Resistance Characteristic Table
• Tolerance of sensor resistance is ±5 %.
• Leave the sensor at measuring temperature for more than 3 minutes when measuring sensor resistance.
(necessary due to detecting speed)
• It is desirable to use digital tester as analogue tester has wider measuring temperature.
• Disassemble refrigerator sensor 1 and 2 from CON8 of main PWB assembly and measure it with digital tester.
• Disassemble freezer sensor from CON7 of main PWB assembly and measure it with digital tester.
MICOM CIRCUIT DESCRIPTION
- 42 -
Measured Temperature (°C)
Freezer Sensor
Refrigerator Sensor 1 and 2, Defrost Sensor and
Open Air Sensor
-20 °C
22.3 k
Ω
77 k
Ω
-15 °C
16.9 k
Ω
60 k
Ω
-15 °C
13.0 k
Ω
47.3 k
Ω
-5 °C
10.1 k
Ω
38.4 k
Ω
0 °C
7.8 k
Ω
30 k
Ω
+5 °C
6.2 k
Ω
24.1 k
Ω
+10 °C
4.9 k
Ω
19.5 k
Ω
+15 °C
3.9 k
Ω
15.9 k
Ω
+20 °C
3.1 k
Ω
13 k
Ω
+25 °C
2.5 k
Ω
11 k
Ω
+30 °C
2.0 k
Ω
8.9 k
Ω
+40 °C
1.4 k
Ω
6.2 k
Ω
+50 °C
0.8 k
Ω
4.3 k
Ω