2. Refrigerator Weak Cooling and Over Cooling Compensation Circuit
• The above option circuit is to compensate the refrigerator compartment temperature by cutting during service.
MICOM CIRCUIT DESCRIPTION
- 40 -
WEAK COOLING
OVER COOLING
COMPENSATION
COMPENSATION
REFRIGERATOR COMPARTMENT
REMARKS
JCR3
JCR4
JCR1
JCR2
TEMPERATURE COMPENSATION
0 °C (FACTORY SHIPPING)
CUT
-1 °C
CUT
-1 °C
CUT
+1 °C
CUT
+1 °C
CUT
CUT
-2 °C
CUT
CUT
+2 °C
CUT
CUT
0 °C
CUT
CUT
0 °C
CUT
CUT
0 °C
CUT
CUT
0 °C
CUT
CUT
CUT
-1 °C
CUT
CUT
CUT
+1 °C
CUT
CUT
CUT
CUT
0 °C
Temperature Compensation by Cutting
JCR1
+1 °C
+2 °C
JCR2
+1 °C
JCR3
-1 °C
-2 °C
JCR4