1. Monitor Panel
1-1. GR-P247, GR-P207, GR-L247, GR-L207
1-2. GR-C247, GR-C207, GR-B247, GR-B207, GR-B197
2. Description of Function
2-1. Funnction of Temperature Selection
* The temperature can vary ±3 °C depending on the load condition.
*( ) : 127V/60Hz, 110~115V/60Hz, 115V/60Hz Rating ONLY.
*< > : TAIBEI
1. When power is initially applied or reapplied after power cut, “Medium” is automatically selected.
2. When the temperature selection switch in the freezer and refrigerator compartments is pressed, the light is on in the
following sequence:
"Medium"
➝
"Medium Max"
➝
"Max"
➝
"Min"
➝
"Medium Min"
➝
"Medium"
3. The temperature setting condition of freezer and refrigerator compartments shall not be indicate in the standard model
(GR-P247, GR-P207, GR-L247, GR-L207, GR-C247, GR-C207, GR-B247, GR-B207) when refrigerator or home bar
door is closed.
MICOM FUNCTION
- 25 -
FRZ
Temp
REF
Temp
SELECT
Max
Min
Function Monitor
Freezer compartment
temperature control Button
Refrigerator compartment
temperature control Button
Dispenser selection button
1
2
3
4
5
5
Max
Max
Min
4
3
2
1
FRZ
Temp
REF
Temp
Division
Power Initially On
1st Press
2nd Press
3th Press
4th Press
Change of
Indication Lamp
Temperature
Control
Medium
Medium Max
Max
Min
Medium Min
Freezer
-19 °C
-22 °C
-23 °C
-15 °C
-17 °C
Control
(-18 °C)
(-20.5 °C)
(-22 °C)
<-19 °C>
<-20.5 °C>
<-22 °C>
<-16.5 °C>
<-18 °C>
Refrigeration
3 °C
1.5 °C
0°C
6 °C
4.5 °C
Control
(7 °C)
<2 °C>
<1 °C>
<0 °C>
<4.5 °C>
<3 °C>
FRZ
Temp
REF
Temp
FRZ
Temp
REF
Temp
FRZ
Temp
REF
Temp
FRZ
Temp
REF
Temp
FRZ
Temp
REF
Temp
Max
Min
Max
Min
Max
Min
Max
Min
Max
Min
Summary of Contents for LRSPC2031BS
Page 46: ...1 GR P247 GR P207 GR L247 GR L207 MICOM CIRCUIT DESCRIPTION 46 GR L247 207 GR P247 207 WORK ...
Page 47: ...2 GR C247 GR C207 GR B247 GR B207 GR B197 MICOM CIRCUIT DESCRIPTION 47 JCR1 JCR2 JCR3 JCR4 ...
Page 51: ...MICOM CIRCUIT DESCRIPTION 51 Freezer Temp Control Refrigerator Temp Control ...
Page 58: ...CIRCUIT 58 GR B247 GR B207 GR C247 GR C207 GR B197 ...