Note1) The freezer and refrigerator temperature displays are also used to display error codes. The exception is that when
the ambient temperature sensor fails, it shows Er in the ambient temperature display. All other display elements will
function normally.
Note2) The R2 sensor, Optichill sensor, and water tank sensor are not indicated in the error codes, but you can see these
errors by entering the test mode by pressing and holding the Freezer Temperature and Super Freezer buttons
simultaneously.
R2-sensor (middle room)
Normal: LED or LCD graphic on the (C) part turns on
Abnormal: LED or LCD graphic on the (C) part turns off
Optichill sensor
Normal: LED or LCD graphic on the (D) part turns on
Abnormal: LED or LCD graphic on the (D) part turns off
Water tank sensor
Normal: LEDs or LCDs graphic on the (E) part turns on
Abnormal: LEDs or LCDs graphic on the (E) part turns off
✻
LCD (LED) check function: LCD (LED) Press and hold the Express Freeze button and the Freezer Temperature
adjustment button to check the display. This will turn on the backlight and all display elements.
Release the buttons and the display will return to its usual state.
MICOM FUNCTION
- 27 -
The other LED or
LCD Graphics
Turn On.