2-8. Control of variable type of freezing fan
1. To increase the cooling speed and load response speed, the MICOM switched the freezer compartment fan motor
between high and regular speeds.
2. The MICOM runs the freezer fan at high speed only at initial power-up, Express Freezing operation, or in response to a
high load. The fan runs at the regular speed in all other circumstances.
3. When you open the refrigerator door while the fan is running at high speed, the MICOM will switch the fan to regular
speed. If you open the freezer door or the home bar door, the fan is switched off.
4. If the MICOM determines the fan is obstructed (the blade cannot turn) it switches the fan off. When there is no fan rotation
signal for 115 seconds, the MICOM displays the error on the display. To restart the fan, clear the obstruction and turn the
power off and back on.
2-9. Control of cooling fan motor
1. The cooling fan is switched ON and OFF in conjunction with the compressor.
2. The cooling fan runs at a single speed.
3. Failure sensing method is same as in fan motor of freezing fan motor (refer to failure diagnosis function table for failure
display).
2-10. Door opening alarm
1. Buzzer generates alarm sound if doors are not closed even when more than a minute consecutively has passed with
doors of freezing/cold storage room or home bar opened.
2. If the doors are left open for more than one minute, the buzzer sounds three
1
/
2
-second tones at thirty second intervals for
four times.
3. If all the doors of freezing/cold storage room or home bar are closed during door open alarm, alarm is immediately
released.
2-11. Ringing of button selection buzzer
1. The DING sounds if you press any button on the front display.
MICOM FUNCTION
- 23 -
Doors of freezing /
cold storage room
or home bar
BUZZER
Closing
Opening
Within
a minute
A minute
30
seconds
30
seconds
30
seconds
Opening
Closing
Closing
3 Times 3 Times 3 Times 3 Times