4-3
Oven lamp
Components
Test procedures
Results
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
5
Ω
± 10%
If not replace
Broil or bake igniter
Oven (safety) valve
Ignition switch
1. Refer to page 3-15 ~ 3-17 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: 45
Ω
~ 100
Ω
(Room Temperature
Resistance)
If not replace
1. Refer to page 3-27 or 3-28 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: Approximately
1 ~ 3
Ω
If not replace
1. Refer to page 3-12 for servicing procedure.
2. Measure the resistance by rotating the cam of
each switch slowly.
(Multiple meter scale : R x 1)
approximately
40° ~ 80°
other
Continuity
Upside
Downside
Infinite