3-6
COMPONENT ACCESS
REMOVING POWER CONTROL
REMOVING POWER CONTROL
BOARD (PCB)
BOARD (PCB)
1. Turn off the electrical supply and gas supply
going to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Remove wire cover & control cover (See step
3~4 on page 3-3)
4. There are 3 PCB's (power control board). When
you check PCB, check the proper pcb in default
mode and check main pcb.
NOTE: Refer to the page 6-1~6-2 for
composition of control board
Power Supply PCB
Main PCB
Relay PCB
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
For Model
Product Code
LRG3091ST /01
FG4124ES.FS1ELGA
LRG3091SB /01
FG4124EB.FB1ELGA
LRG3091SW /01
FG4124EW.FW1ELGA
LRG3091ST /02
FG4124ES.FS2ELGA
LRG3091SB /02
FG4124EB.FB2ELGA
LRG3091SW /02
FG4124EW.FW2ELGA