![LG LRG3060ST Service Manual Download Page 35](http://html.mh-extra.com/html/lg/lrg3060st/lrg3060st_service-manual_218350035.webp)
4-2
Components
Test procedures
Results
Door switch
1. Refer to page 3-8 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Oven lamp
1. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
5 Ω ± 10%
If not replace
Broil or bake igniter
1. Refer to page 3-9~3-10 for servicing procedure.
2. Measure the resistance after cooling down.
(Multiple meter scale : R x 1)
Normal: 45 Ω ~ 400 Ω
(Room Temperature
Resistance)
If not replace
Continuity
Infinite