4-8
Components
Test procedures
Results
Center Rear(CR)
Element
: Warming Zone
(Plane Heater)
1. Refer to page 3-7 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal E1 and E2.
The meter should indicate 570Ω ± 10%
Normal: Approximately 570 Ω,
If not replace
5. Touch the ohmmeter test leads to limiter
terminals 1A and 2A
With the temperature below 150°F, the meter
should indicate an open circuit(infinite).
With the temperature above 150°F, the meter
should indicate continuity (0Ω).
Below 150°F
open circuit(infinite).
Above 150°F
continuity (0 Ω)
1A
2A
2E
1E
1A
2A
2E
1E