- 67 -
14-1-7 CONTROL OF FREEZER FAN MOTOR
1. Freezer fan motor has high and standard speeds.
2. High speed is used at power-up, for Ice Plus, and when refrigerator is overloaded.
Standard speeds is used for general purposes.
3. To improve cooling speed, the RPM of the freezer fan motor change from normal speed to high.
4. High speed (2700RPM) : Initial power on or load corresponding operation, Ice Plus
Normal speed (2400RPM) : General working conditions.
5. Fan motor stops when refrigerator or freezer door opens.
14-1-8 Cooling Fan Motor
1. The cooling fan is switched ON and OFF in conjunction with the compressor.
2. The cooling fan runs at a single speed.
3. The Failure sensing mathod is the same as in the fan motor of the freezing fan motor(refer to failure diagnosis function
table for failure display).
14-1-9 Icing Fan
1. The Icing Fan is controlled by the the sensor on the top of the ice room.
2. The Failure sensing mathod is the same as in the fan motor of the freezer.
(refer to failure diagnosis function table for failure display)
14-1-5 Ice Plus selection
Please select this function for quick freezing.
• When you press the Ice Plus Button, the Ice Plus ICON will be
turned on again.
• Ice Plus function automatically turns off after a fixed time passes.
14-1-6 Dispenser use selection
You can select water or ice by separated pad switch.
• When you press ice type button, ice type will be changed. (Crush or
Cube)
• Hold your cup in the dispenser for a few seconds after dispensing
ice or water to allow the last pieces of ice drops of water to fall into
the cup.
• When after initially establ ishing the water comes out, the water tank
inside fills and until at the time of quality the hour is caught.
WATER PAD
ICE PAD