- 39 -
9-6 Poor cooling in Fresh food section
No
1
Checking flow
Check the sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and
Check the air flow.
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
<CON4>
Temperature
23°F / -5°C
32°F / 0°C
41°F / 5°C
50°F / 10°C
59°F / 15°C
Result
38
30
24
19.5
16
Status
Airflow
No airflow
SVC Action
Go to the 4
Check the R Fan motor
Check the damper
(Go to the 6)
4
Check the air temperature.
Cold or not?
Status
Cold
Not cold
SVC Action
Normal
Check the Compressor
And sealed system