7-19
(2) CHECKOUT PROCEDURES FOR RELAY.
- PROBLEM (A) -
FAN motor and oven lamp turn on without touching
START key when the door is closed.
Remove the mate connector of I/O
CON from the circuit board.
Does the unit still operate?
GOOD
Replace the
circuit board
Replace
RELAY1
- PROBLEM (B) -
FAN motor and oven lamp turn on When the door is
closed and START key is touched.
Measure the voltage at pin NO.
35 of U01
Voltage reading: 0 Vdc
10 of U03
Voltage reading: about 15V
Replace the
circuit board
Defective
RELAY1 or poor
connection of
RELAY1
Defective
RELAY1
Replace
RELAY1 or correct
the connection.
NO
NO
YES
YES
NO
NO
YES
YES
GOOD
Summary of Contents for LMV1925SB
Page 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Page 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD CUSTOM SET CUSTOM COOK Q DEFROST Ez On ...
Page 38: ...8 2 CONTROL PANEL 24781M 24810P 23572A 07 268711 WTP013 WTT029 23506A EV ...
Page 40: ...8 4 LATCH BOARD 466001 43501A 43500A 466003 466001 44510A WSZ084 EV ...
Page 44: ...8 14 SCHEMATIC DIAGRAM OF P C B ...
Page 45: ...8 15 PRINTED CIRCUIT BOARD ...