Operation Details
1. MAIN UNIT FUNCTION
• DISPLAY
1) C/O Model
Operation Indicator
• On while in appliance operation, off while in appliance pause
• Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)
Sleep Timer Indicator
• On while in sleep timer mode, off when sleep timer cancel or appliance operation pause
Timer Indicator
• On while in timer mode (on/off), off when timer mode is completed or canceled.
Comp. Running Incidator
• While in appliance operation, on while in outdoor unit compressor running, off while in compressor off
2) H/P Model
Operation Indicator
• On while in appliance operation, off while in appliance pause
• Flashing while in disconnection or short in Thermistor (3 sec off / 0.5 sec on)
Sleep Timer Indicator
• On while in sleep timer mode, off when sleep timer cancel or appliance operation pause
Timer Indicator
• On while in timer mode (on/off), off when timer mode is completed or canceled
Defrost Indicator
• Off except when hot start during heating mode operation or while in defrost control
■
Cooling Mode Operation
• When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan
stop.
• When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp
➲
Setting Temp+0.5°C
Compressor OFF Temp
➲
Setting Temp-0.5°C
• While in compressor running, operating with the airflow speed set by the remote control. While in compressor
not running, operating with the low airflow speed regardless of the setting.
■
Healthy Dehumidification Mode
• When the dehumidification operation input by the remote control is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C
≤
Intake Air Temp
➲
25°C
24°C
≤
Intake Intake Air Temp<26°C
➲
Intake Air Temp-1°C
18°C
≤
Intake Intake Air Temp<24°C
➲
Intake Air Temp-0.5°C
Intake Air Temp<18°C
➲
18°C
-19-
Summary of Contents for LM-2561C3L
Page 12: ... 12 LM 4260H3L M 900 1 225 370 ...
Page 57: ... 57 Electronic Control Device 1 Indoor MAIN P C B ASM ...
Page 58: ... 58 2 Outdoor MAIN P C B ASM LM 2561C3L LM 4260H3L M ...
Page 59: ... 59 MAIN P C B ASM LM 2860C5L LM 3060H4L M ...
Page 60: ... 60 3 Display Ass y ...
Page 61: ... 61 Schematic Diagram 1 Indoor LM 2561C3L LM 2860C5L LM 3060H4L M LM 4260H3L M ...
Page 62: ... 62 2 Outdoor LM 2561C3L LM 4260H3L M ...
Page 63: ... 63 LM 2860C5L LM 3060H4L M ...
Page 82: ...P No 3828A20023R January 2001 Printed in Korea ...