SAFETY

The instructions related to the safety indicated in the

following are for preventing unexpected danger or

damage in advance by safely and exactly using the product.

DANGER

WARNING

CAUTION

Non-compliance of the instructions may immediately

Non-compliance of the instructions may cause death or

Non-compliance of the instructions may cause injury or

cause serious injury or death.

DANGER

Do not contact electrically active 

parts of the panel, such as 

terminals, without appropriate 

safety gear. Contact may result in 

lethal spark or electric shock.

Do not use or install if the module 

is broken or torn. Failure to 

comply may result  in electric 

shock.

WARNING

Perform all work in dry conditions 

and use only dry tools. Do 

not handle wet panels without 

appropriate protection equipment. 

Failure to comply may result in 

accident or death.

Damaged modules must be 

treated with safety protection 

equipment. Failure to comply 

may result in serious bodily injury 

or death.

No electrical parts like cables are 

located after installation between 

laminate and mounting structure. 

Do Not reconnect or repair 

junction box cable. It may occur 

spark or electric shock.

Do not bending junction box's 

cable. While under stress, it may 

occur module damage. Cable 

bending radius should be more 

than 4 times the cable diameter, 

at least.

CAUTION

Use proper equipment, 

connectors, wires and buttresses 

for the installation of the module. 

Failure to comply may result in 

product damage, product failure 

or bodily injury. 

Installation during rain, heavy 

wind or snowy day may result in 

bodily injury or death.

Holes in the frame or glass of 

the module may decrease the 

strength of the frame or break the 

glass.

serious injury to the user.

property damage to the user.

Do not approach the damaged 

or broken module unless you are 

Failure to comply may result in 

serious bodily  injury or death.

an authorized or qualified expert.

Summary of Contents for LG425N2T-E6

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 www lg solar com Installation manual PV Solar MODULE ...

Page 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 14 16 17 APPE...

Page 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Page 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Page 5: ...icro fiber cloth can be used for regular washing or It may result in a burn or injury Do not disassemble the solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Do ...

Page 6: ... connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc...

Page 7: ...rks should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and location of grounding holes is provided in Product One M4 stainless steel bolt one nut one spring washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts wash...

Page 8: ... is no shadowing affected by building chimney tree and neighboring module etc Mounting Rails No of Cell Do not use module to replace or partly replace roofs and walls of living places Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it faces the sun directly The tilt angle of the modules should be s...

Page 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Page 10: ...the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorized WEEE collection point For the m...

Page 11: ...2 40 LG450N2W E6 AW5 450 0 3 24 20 1500 2110 1042 40 LGXXXN2W E6 AW5 LGXXXN2T E6 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV C...

Page 12: ...325 38 7 8 39 46 3 8 81 435 328 39 0 8 42 46 6 8 86 440 332 39 3 8 46 46 9 8 91 MPP Voltage Vmpp V MPP Current Impp A Open Circuit Voltage Voc V Short Circuit Current Isc A Temperature Characteristics PRODUCT SPECIFICATIONS NMOT Nominal Module Operating Temperature Irradiance 800W m ambient temperature 20 wind speed 1m s 2 12 42 3 0 33 0 26 0 04 LGXXXN2W E6 Model 430 Maximum Power Pmax W 325 38 2 ...

Page 13: ...13 Dimensions of Modules LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 Unit mm in Note Cable length with connector MC4 05 8 PV CO02 Note Cable length with connector MC4 05 8 PV CO02 ...

Page 14: ... Position mm 250 400 5400 3000 Load Front Rear Pa Position mm 0 300 5400 1600 Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Fig 1 Bolting type M8 Fig 2 Clamping Type Fig 4 Clamping Type Fig 5 Clamping Type Fig 6 Clamping Type Mechanical Installation 72Cell Model Load Front Rear Pa Position mm N2W 343 N2T 353 5400 3000 Fig 3 Clamping Type ...

Page 15: ...2400 1500 1500 A Load Front Rear Pa Position mm 0 300 250 400 2400 1600 A B Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Load Front Rear Pa Position mm 250 400 3000 3000 Fig 10 Bolting type M6 Fig 7 Clamping Type Fig 8 Clamping Type Fig 9 Clamping Type APPENDIX Mechanical Installation 72Cell Model 853 ...

Page 16: ...our spring washers and eight flat washers are recommended per solar module Bolting Method Clamp system requirements Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touched with the module s glass Use appropriate bolted connections as per clamp manufacturer s in...

Page 17: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Page 18: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...

Reviews: