BEFORE & AFTER INSTALLATION

Before Installation

Please carefully read this manual before installation.

Solar module installation and maintenance must be 

All installation instructions should be read and  
understood before  performing any installation.

Do not touch the solar module with bare hands.

After Installation

Plug in the connector tightly and ensure that the wiring 
properly works.

Conduct periodic inspection of the panels for damage 
to front glass, back sheet, frame, junction box, or 
external electrical connections.

Check electrical connections for loose connections 
and corrosion.

PV panels can operate effectively without ever being washed,

output.

performed by qualified and authorized installer.

although removal of dirt from the front glass can increase

Water, ethanol or a conventional glass cleanser with 

rinsing of the front glass to remove dust, dirt or other 
deposits.
Do not use ground water containing calcium carbonate
components when cleaning glass.

Aggressive and abrasive cleansers or chemicals such 
as alkali chemicals including ammonia based solution 
should not be used on cleaning the module.

Always keep the back surface of the panel free from
any foreign objects or structural elements which could
come into contact with the panel, especially when the
panel is under mechanical load.

Deposits of foreign material on the frame surface can 
be cleaned by using a wet sponge or cloth and dried 
in air or by using a clean chamois.

Perform the wiring work by connecting the connector 
and wires to the stand away from the roof or ground. 

Do not use any kind of oil or lubricant on the module's
any parts, It can defect the PV Module.

a micro-fiber cloth can be used for regular washing or

It may result in a burn or injury.

Do not disassemble the solar module.

After installation or repair, check that the solar module 
are operating properly.

In the event that the currently used solar module or 
parts have been replaced the newly replaced module 
and parts must have the same model name and parts 
as the previously installed solar module.

Do not let anyone approach the solar module who has
little knowledge of solar modules or on the measures to
take when solar modules are damaged in order to avoid
the risk of injury or electrical shock.

Secure all necessary permits and licenses to install 
the solar modules.

Do not locate the solar module horizontally, as this may
cause dirt or white efflorescence(glass deformation).

Panels are not intended for use indoors or on moving 
vehicles of any kind.

conditions of 1000W/m  irradiance and 25°C (77°F)  
solar cell temperature. Colder temperatures may 
substantially increase voltage and power. 

Keep the solar module and system away from children 
at all times.

Keep the module packed in the carton until the time of 
installation.

site.

Do not work alone. Please work as part of a team of 
two or more people.

Safety harness use is strongly recommended for  
installation.

Partial shadowing may substantially reduce panel and 
system output and may be the reason for the damage 
of solar module.

Care must be taken to avoid low tilt angles which may 
cause dirt to buildup on the glass against the frame 
edge.

Dirt build-up on the surface of the panel may 
cause active solar cells to be shaded and electrical 
performance to be impaired.

Industry standard rated specifications are made at

Keep flammable gasses away from the installation

2

Be careful not to damage the cable when using a tool  
such as a knife to remove the cable tie that fixes the
junction box cable.

Summary of Contents for LG425N2T-E6

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 www lg solar com Installation manual PV Solar MODULE ...

Page 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 13 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 14 16 17 APPE...

Page 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Page 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Page 5: ...icro fiber cloth can be used for regular washing or It may result in a burn or injury Do not disassemble the solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Do ...

Page 6: ... connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc...

Page 7: ...rks should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and location of grounding holes is provided in Product One M4 stainless steel bolt one nut one spring washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts wash...

Page 8: ... is no shadowing affected by building chimney tree and neighboring module etc Mounting Rails No of Cell Do not use module to replace or partly replace roofs and walls of living places Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it faces the sun directly The tilt angle of the modules should be s...

Page 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Page 10: ...the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorized WEEE collection point For the m...

Page 11: ...2 40 LG450N2W E6 AW5 450 0 3 24 20 1500 2110 1042 40 LGXXXN2W E6 AW5 LGXXXN2T E6 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV C...

Page 12: ...325 38 7 8 39 46 3 8 81 435 328 39 0 8 42 46 6 8 86 440 332 39 3 8 46 46 9 8 91 MPP Voltage Vmpp V MPP Current Impp A Open Circuit Voltage Voc V Short Circuit Current Isc A Temperature Characteristics PRODUCT SPECIFICATIONS NMOT Nominal Module Operating Temperature Irradiance 800W m ambient temperature 20 wind speed 1m s 2 12 42 3 0 33 0 26 0 04 LGXXXN2W E6 Model 430 Maximum Power Pmax W 325 38 2 ...

Page 13: ...13 Dimensions of Modules LGXXXN2W E6 LGXXXN2W E6 AW5 LGXXXN2T E6 Unit mm in Note Cable length with connector MC4 05 8 PV CO02 Note Cable length with connector MC4 05 8 PV CO02 ...

Page 14: ... Position mm 250 400 5400 3000 Load Front Rear Pa Position mm 0 300 5400 1600 Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Fig 1 Bolting type M8 Fig 2 Clamping Type Fig 4 Clamping Type Fig 5 Clamping Type Fig 6 Clamping Type Mechanical Installation 72Cell Model Load Front Rear Pa Position mm N2W 343 N2T 353 5400 3000 Fig 3 Clamping Type ...

Page 15: ...2400 1500 1500 A Load Front Rear Pa Position mm 0 300 250 400 2400 1600 A B Load Front Rear Pa Position mm 0 50 100 750 2400 2400 A B Load Front Rear Pa Position mm 250 400 3000 3000 Fig 10 Bolting type M6 Fig 7 Clamping Type Fig 8 Clamping Type Fig 9 Clamping Type APPENDIX Mechanical Installation 72Cell Model 853 ...

Page 16: ...our spring washers and eight flat washers are recommended per solar module Bolting Method Clamp system requirements Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touched with the module s glass Use appropriate bolted connections as per clamp manufacturer s in...

Page 17: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Page 18: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...