background image

4

 

 

Before & After Installation

 

 

Before Installation

 

Please  carefully  read  this  manual  before 
installation. 
• Solar module installation  should  be performed by 

an  authorized    installer    for    the    safety    and 
maintenance of the system. 

•  All  installation  instructions  should  be  clearly 

understood before attempting installation. 

• Do not twist, pull, or scratch the cable attached to 

the solar module. 

• Do not touch the solar module with bare hands. It 

may result in a burn or injury. 

•  Do  not  drop  the  solar  module  and  cause  an 

excessive load on solar module. 

• Do not disassemble the solar module. 
•  After  installation  or  repair,  check  whether  solar 

module operates properly or not. 

•  In  case  the  currently  used  solar  module  or  the 

parts  applied  to  the  solar  module  have  been 
replaced,  check  whether  the  changed  solar 
module  is  properly  operated  or  not.  The  newly 
replaced  solar  module  and  its  parts  must  be  the 
same solar module (module name) and parts with 
the current solar module. 

•  Please  contact  the  local  office  to  confirm  the 

regulations and to obtain permission. 

•  Do  not  let  anyone  approach  the  solar  module 

who  has  little  knowledge  of  solar  modules  or  on 
the  measures  to  take  when  solar  modules  are 
damaged  in  order  to  avoid  the  risk  of  injury  or 
electrical shock. 

•  Do  not  locate  the  solar  module  horizontally,  as 

this  may  cause  dirt  or  white  efflorescence  (glass 
deformation) 

•   Panels    produce    voltage    even    when    not 

connected to an electrical circuit or load. 

•  Panels  are  intended  for  outdoors,  land  based 

applications only. Panels are not intended for use 
indoor  use  or  application  on  moving  vehicles  of 
any kind. 

•  Reflection  from  external  environments  such  as 

snow,  water  or  other  surfaces  can  increase  the 
power generated by the panel. 

•  Industry  standard  rated  specifications  are  made 

at  conditions  of  1000W/m

irradiance  and  25°C 

(77ºF)  solar  cell  temperature.  Colder  temperatur- 
es can substantially increase voltage and power. 

•  Keep  the  solar  module  and  system  away  from 

children when installing. 

•  Keep  the  module  packed  in  the  carton  until  the 

time of installation. 

•  Make  sure  flammable  gases  are  not  generated 

near the installation site. 

• Do not work alone. Please work as part of a team 

of two or more people. 

•  Wear  a  safety  belt  if  working  high  above  the 

ground. 

• Contact with electrically active parts of the panels, 

such as terminals, can result in burns, sparks and 
lethal  shock  whether  the  panel  is  connected  or 
disconnected. 

•  Even  partial  shadowing  can  substantially  reduce 

panel and system output. 

• Care must be taken to avoid low tilt angles which 

may cause dirt to buildup on the glass against the 
frame edge. 

•  Dirt  build-up  on  the  surface  of  the  panel  can 

cause  active  solar  cells  to  be  shaded  and 
electrical performance to be impaired. 

•  Always  keep  the  back  surface  of  the  panel  free 

from  any  foreign  objects  or  structural  elements 
which  could  come  into  contact  with  the  panel, 
especially  when  the  panel  is  under  mechanical 
load. 

•  For  permission  to  use  mounting  methods  not 

described  in  the  Mounting  Guide  please  consult 
LG  Solar.  Failure  to  do  so  will  void  the  warranty 
and panel certification. 

 

After Installation

 

• 

 

Plug the connector in tightly and ensure that the 

wiring properly works. 

•  It  is  advisable  to  conduct  periodic  inspection  of 

the panels for damage to front glass, back sheet, 
frame,  junction  box,  or  external  electrical 
connections. 

•  Check  electrical  connections  for  loose  connec- 

tions and corrosion. 

•  PV  panels  can  operate  effectively  without  ever 

being  washed,  although  removal  of  dirt  from  the 
front glass can increase output. 

• Water,  ethanol  or  a  conventional  glass  cleanser 

with  a  micro-fiber  cloth  can  be  used  for  regular 
washing  or  rinsing  of  the  front  glass  to  remove 
dust, dirt or other deposits. 

•  No    aggressive    and    abrasive    cleansers    or 

chemicals  such  as  alkali  chemicals  including 
ammonia  based solution  should  ever  be  used  on 
the treated front glass. 

•   Always    wear    rubber    gloves    for    electrical 

insulation  while  maintaining,  washing  or  cleaning 
panels. 

• Deposits of foreign material on the frame surface 

can  be  cleaned  using  a  wet  sponge  or  cloth  and 
dried in air or by using a clean chamois. 

•  Perform  the  wiring  work  by  connecting  the 

connector  and  wires  to  the  stand  away  from  the 
roof or ground. 

Summary of Contents for LG300N1T-A5

Page 1: ...tallation manual PV Solar MODULE Please read this manual carefully before operating your set and retain it for future reference N TYPE MODEL LGXXXN1T A5 LGXXXN2T A5 P NO MFL69668602 Rev 00 www lg solar com ...

Page 2: ...ation 5 4 Mechanical Installation 6 5 Product Specifications 8 6 Disclaimer of Liability Disposal 10 7 Transporting and Storage 10 8 Appendix 11 Revisions Table Date Version Description of change Remark 2016 12 20 1 0 1st edition Publish Installation Manual 2017 08 14 2 0 Change M Load Spec ...

Page 3: ...Cable bending radius should be more than 4 times the cable diameter at least Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the streng...

Page 4: ...d in the carton until the time of installation Make sure flammable gases are not generated near the installation site Do not work alone Please work as part of a team of two or more people Wear a safety belt if working high above the ground Contact with electrically active parts of the panels such as terminals can result in burns sparks and lethal shock whether the panel is connected or disconnecte...

Page 5: ...ermined by basis on max system voltage the 125 safety factor and the module Voc which can be checked in Product Specifications in this document Series connection for more voltage Parallel Connection The solar modules may be combined in parallel to produce the desired current output When modules are combined in parallel the total current is equal to the sum of currents from each module The voltage ...

Page 6: ...ounding wire Flat washer Spring washer Nut Module Mounting The LG Electronics LGE Limited Warranty for solar modules is contingent upon modules being mounted in accordance with the requirements described in this section The solar modules are in Application Class A and have the Safety Class II Therefore they can be operated in systems with 120 V DC and higher General access is not restricted Site C...

Page 7: ...thods Torque 8 12Nm When installing modules in heavy snow areas special care should be taken to install the modules in a manner that provides sufficient design strength while meeting local code requirements Mounting by using frame bolts holes Secure the solar module to the structure using the factory mounting holes Four M8 stainless steel bolts four nuts four spring washers and eight flat washers ...

Page 8: ...G335N1T A5 Yes 335 0 3 41 2 10 28 35 1 9 55 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LG340N1T A5 Yes 340 0 3 41 3 10 32 35 5 9 59 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LG345N1T A5 Yes 345 0 3 41 4 10 36 35 9 9 62 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LGXXXN2T A5 LG360N2T A5 Yes 360 0 3 48 6 9 91 38 8 9 29 16 20 1000 MC4 PV JM601A 2064 1024 40 22 0 LG365N2T A5 Yes 365 0 3 48 7 9 95 39 3...

Page 9: ...9 Product Specifications Dimensions of Modules 60Cell Module Unit mm 72Cell Module ...

Page 10: ... should be disposed of separately from the municipal waste stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to con...

Page 11: ...0Pa Fig 5 Clamping Type Fig 6 Clamping Type C A B B A C A B 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind A 200mm B 400mm Front 6000Pa Rear 5400Pa A 120mm 4point Front 1800Pa Rear 1800Pa C 120mm Front 3200Pa Rear 1800Pa A 120mm B 843 100mm 6point Front 6000Pa Rear 540...

Page 12: ...ig 6 Clamping Type C A B B A C A B 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind A 250mm B 400mm Front 5400Pa Rear 4300Pa A 120mm 4point Front 1600Pa Rear 1600Pa C 120mm Front 3200Pa Rear 1600Pa A 120mm B 1012 100mm 6point Front 5400Pa Rear 4300Pa Note All mechanical ...

Page 13: ...rs are recommended per solar module Clamp system requirements The clamp should not be touched with the module s glass Use corrosion resistant material clamps and hardware If you use a special clamp it needs to test for compatibility by LGE Use appropriate bolted connections as per clamp manufacturer s instructions Follow the clamp manufacturer s recommended applied torque to fasten the clamps Widt...

Page 14: ...n 1 Module height 0 6 1 5m 2 Albedo 0 15 0 85 3 Tilt angle 30º south face latitude 36º 4 Array distance 4 5m Racking Scene 2 lows landscape installation 1 low portrait installation H H H is a minimum height from mounting ground to module LGE recommended a minimum height of 1m ...

Page 15: ...8 Yeoui daero Yeongdeungpo gu Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II A5 T IEC V1 EN 201612 ...

Reviews: