background image

3

 

 

 

 

 

 

 

 

Safety

 

 

 

The  instructions  related  to  the  safety  indicated  in 

the following are for preventing unexpected danger 

or damage in  advance  by safely and exactly using 

the product. 

 

Non-compliance  of  the  instructions  may  immedia- 

tely cause serious injury or death. 

 

Non-compliance  of  the  instructions  may  cause 

death or serious injury to the user. 

 

 

Non-compliance  of  the  instructions  may  cause 

injury or property damage to the user. 

 

Do  not  contact  with  electrically  active  parts  of 

the  panel,  such  as  terminals,  regardless  of 

connection  of  the  module.  It  may  result  in  spark 

or lethal electric shock. 

Please  don’t  use  the  module  with  the  broken 

window or the torn  back  side. There  is  a danger 

of electric shock

.

 

① 

      

 

 

 

   ①

Please perform works in the dry condition and 

use  only  dry  tools.  Do  not  handle  the  wet  panels 

without  protection  equipment.  It  may  result  in 

safety accident. 

Damaged  module  must  be  treated  with  safety 

protection equipment. It may result in injury. 

Do not approach the damaged or broken module 

unless you are an expert. It may result in serious 

injury. 

No  electrical  parts  like  cables  are  located  after 

installation  between  laminate  and  mounting 

structure. 

Do  Not  reconnect  or  repair  Junction  box  Cable. 

It may occur spark or electric shock. 

Do   not   bending   junction   box's   cable.   While 

under   stress,   it   may   occur   module   damage. 

Cable bending radius should be more than 

4 times the cable diameter, at least. 

 

 

 

Please  use  proper  equipment,  connector,  wire 

and  buttress  for  system  configuration  of  the 
module.  It  may  result  in  damage  or  failure  of  the 
product. 

Do   not   perform   installation   in   rainy,   heavily 

windy  or    snowy    days.    It  may  result  in  safety 
accident. 

Do  not  make  holes  in  the frame  or glass  of  the 

module.  It  may   decrease   the   strength   of  the 
frame or break the glass. 

Do  not  touch  the  glass  surface  or  frame  of  the 

solar  module  after  installation  of  the  module.  It 
may result in injury. 

Do  not  locate  a  heavy  object  onto  the  module. 

Do  not  stand  on  or  step  on  the  module.  Do  not 
drop  or  suddenly  lay  down  the  module.  It  may 
result in injury. 

Do not scratch the coating surface of the frame. 

It may decrease the strength  due to corrosion  of 
the frame. 

Do   not   concentrate   sunlight   on   the   module 

surface. It may result in damage of the product. 

Do  not  apply  a  shock to the junction  box  of the 

module  or  pull  the  cable.  Do  not  remove  the 
labels  attached  to  the  module.  It  may  result  in 
damage of the product. 

If  the  installing  structure  has  a  curved  surface 

e.g. arch type as shown  in  the below picture,  do 
not  forcefully  modify  the  module  in  installation 
when  connecting  it  with  the  structure.  Please 
install the module in the place where the structure 
has been completely set up because deformation 
of  the  structure  may  cause  deformation  of  the 
product  when  performing  installation  by  using  a 
crane,  etc  after  assembling  the  module  to  the 
installing structure. 

①   

     ②  

    ③ 

 

 

④    

 

⑤        ⑥ 

 

 

⑦             ⑧ 

 
 

⑨ 

Summary of Contents for LG300N1T-A5

Page 1: ...tallation manual PV Solar MODULE Please read this manual carefully before operating your set and retain it for future reference N TYPE MODEL LGXXXN1T A5 LGXXXN2T A5 P NO MFL69668602 Rev 00 www lg solar com ...

Page 2: ...ation 5 4 Mechanical Installation 6 5 Product Specifications 8 6 Disclaimer of Liability Disposal 10 7 Transporting and Storage 10 8 Appendix 11 Revisions Table Date Version Description of change Remark 2016 12 20 1 0 1st edition Publish Installation Manual 2017 08 14 2 0 Change M Load Spec ...

Page 3: ...Cable bending radius should be more than 4 times the cable diameter at least Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the streng...

Page 4: ...d in the carton until the time of installation Make sure flammable gases are not generated near the installation site Do not work alone Please work as part of a team of two or more people Wear a safety belt if working high above the ground Contact with electrically active parts of the panels such as terminals can result in burns sparks and lethal shock whether the panel is connected or disconnecte...

Page 5: ...ermined by basis on max system voltage the 125 safety factor and the module Voc which can be checked in Product Specifications in this document Series connection for more voltage Parallel Connection The solar modules may be combined in parallel to produce the desired current output When modules are combined in parallel the total current is equal to the sum of currents from each module The voltage ...

Page 6: ...ounding wire Flat washer Spring washer Nut Module Mounting The LG Electronics LGE Limited Warranty for solar modules is contingent upon modules being mounted in accordance with the requirements described in this section The solar modules are in Application Class A and have the Safety Class II Therefore they can be operated in systems with 120 V DC and higher General access is not restricted Site C...

Page 7: ...thods Torque 8 12Nm When installing modules in heavy snow areas special care should be taken to install the modules in a manner that provides sufficient design strength while meeting local code requirements Mounting by using frame bolts holes Secure the solar module to the structure using the factory mounting holes Four M8 stainless steel bolts four nuts four spring washers and eight flat washers ...

Page 8: ...G335N1T A5 Yes 335 0 3 41 2 10 28 35 1 9 55 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LG340N1T A5 Yes 340 0 3 41 3 10 32 35 5 9 59 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LG345N1T A5 Yes 345 0 3 41 4 10 36 35 9 9 62 19 20 1000 MC4 PV JM601A 1730 1024 40 18 2 LGXXXN2T A5 LG360N2T A5 Yes 360 0 3 48 6 9 91 38 8 9 29 16 20 1000 MC4 PV JM601A 2064 1024 40 22 0 LG365N2T A5 Yes 365 0 3 48 7 9 95 39 3...

Page 9: ...9 Product Specifications Dimensions of Modules 60Cell Module Unit mm 72Cell Module ...

Page 10: ... should be disposed of separately from the municipal waste stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to con...

Page 11: ...0Pa Fig 5 Clamping Type Fig 6 Clamping Type C A B B A C A B 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind A 200mm B 400mm Front 6000Pa Rear 5400Pa A 120mm 4point Front 1800Pa Rear 1800Pa C 120mm Front 3200Pa Rear 1800Pa A 120mm B 843 100mm 6point Front 6000Pa Rear 540...

Page 12: ...ig 6 Clamping Type C A B B A C A B 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind A 250mm B 400mm Front 5400Pa Rear 4300Pa A 120mm 4point Front 1600Pa Rear 1600Pa C 120mm Front 3200Pa Rear 1600Pa A 120mm B 1012 100mm 6point Front 5400Pa Rear 4300Pa Note All mechanical ...

Page 13: ...rs are recommended per solar module Clamp system requirements The clamp should not be touched with the module s glass Use corrosion resistant material clamps and hardware If you use a special clamp it needs to test for compatibility by LGE Use appropriate bolted connections as per clamp manufacturer s instructions Follow the clamp manufacturer s recommended applied torque to fasten the clamps Widt...

Page 14: ...n 1 Module height 0 6 1 5m 2 Albedo 0 15 0 85 3 Tilt angle 30º south face latitude 36º 4 Array distance 4 5m Racking Scene 2 lows landscape installation 1 low portrait installation H H H is a minimum height from mounting ground to module LGE recommended a minimum height of 1m ...

Page 15: ...8 Yeoui daero Yeongdeungpo gu Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II A5 T IEC V1 EN 201612 ...