Checking Flow
START
YES
Check Battery Voltage
> 3.2V ?
NO
Charge of Change Battery and try again
Replace U201
Re-download Software
Check the contact of power-key
or dome switch
Push power-on key and check
the level change of
R404
Check the voltage of
the following port at U201
+1.2V_MSMC
+2.6V_MSMP
+2.65V_MSMA
+2.85V_TCXO
+2.6V_RX
+2.6V_TX
YES
YES
NO
NO
YES